Set remote to “only open” gate
#1
On Rigel 6 a button press on our remotes will:
Pressed whilst closed -> open
Pressed during opening -> stop
Pressed whilst stopped -> close or open (depending on what they were doing before they were stopped)

However we would like to change it so that a button press will only ever open the gates. This avoids the annoying occurrence where one person has clicked to open and another unknowingly presses on their remote and stops the gates. Gate will close automatically after usual delay.

Is it possible to change the settings?
Reply
#2
(17-01-2023, 08:36 AM)mark123499 Wrote: On Rigel 6 a button press on our remotes will:
Pressed whilst closed -> open
Pressed during opening -> stop
Pressed whilst stopped -> close or open (depending on what they were doing before they were stopped)

However we would like to change it so that a button press will only ever open the gates. This avoids the annoying occurrence where one person has clicked to open and another unknowingly presses on their remote and stops the gates. Gate will close automatically after usual delay.

Is it possible to change the settings?

Hi,

This will be done in the parameters. You will need to go into the "logic" section and change "1ch" from "0" to "2". What this is doing is changing the logic of the remote from step by step to open only.

Sam.
EasyGates.co.uk - EasyGates Ltd
 
EasyGates Direct - Trade only accounts.

Smart and Secure Center - Smart Home Products
Reply
#3
Hi Sam,

Thank you for getting back to me on this. I've found the settings on the board but have not yet made the change.

Am I correct in thinking that the change you have proposed would mean that a button press would open the gates and they would remain open? I would like them to close after a time delay. But would also like it set such that a button press will only ever open the gates. 

Really appreciate your input, thanks again.

Mark
Reply
#4
(23-05-2023, 08:46 AM)mark123499 Wrote: Hi Sam,

Thank you for getting back to me on this. I've found the settings on the board but have not yet made the change.

Am I correct in thinking that the change you have proposed would mean that a button press would open the gates and they would remain open? I would like them to close after a time delay. But would also like it set such that a button press will only ever open the gates. 

Really appreciate your input, thanks again.

Mark

I also want to know this thing about the gates. 
Yes the work is must appriciatable.
Reply
#5
Sam’s method worked. Setting it to “open” still means the gates close after the Tca (automatic closing time).

All is covered on the manual. Extracts attached. I’ve scribbled out the password section as we don’t have one set (which is the default setting)


Attached Files Image(s)
       
Reply


Possibly Related Threads…
Thread Author Replies Views Last Post
  Deimos ultra bt a400 Gate to stay open Sootylfc 0 186 04-11-2024, 05:59 PM
Last Post: Sootylfc
  Deimos ultra bt a400 gate - not working with fobs Sootylfc 2 573 15-10-2024, 10:37 AM
Last Post: Sootylfc
  BFT LUX G BT 2B gate won't open or close fully PaulR 1 970 17-07-2024, 02:24 PM
Last Post: benbrooks
  BFT Sliding Gate randomly opening and closing AdrianMate 5 4,256 14-06-2024, 12:12 PM
Last Post: JoeF
  Two BFT pairs of electric gates (one remote) Harry44 1 1,029 04-06-2024, 01:30 PM
Last Post: Aiden Mitton
  Gate radio receiver not working Zhymke 0 663 23-05-2024, 06:35 PM
Last Post: Zhymke
  Gate wont close issue MR_ROBOT 3 11,569 11-04-2024, 08:08 AM
Last Post: JoeF
  Bft gate problem djkokalis 1 2,691 14-02-2024, 12:39 PM
Last Post: JoeF
  Ecosol/Kustos doesn't open and close fully? supremee 3 3,657 09-02-2024, 03:12 PM
Last Post: EdwardBab
  BFT Rigel 4 - single Gate Not Closing Tsnash 1 2,361 04-01-2024, 10:21 AM
Last Post: JoeF

Forum Jump:


Users browsing this thread: 1 Guest(s)