Thread Rating:
  • 7 Vote(s) - 2.86 Average
  • 1
  • 2
  • 3
  • 4
  • 5
BFT Rigel 6 - Buttons suddenly stop working
#1
Morning!

The buttons on my Rigel6 have suddenly stopped working. I've checked the connections for power (50/51) and I can see wires plugged into 60+61 and 60+64. I'm assuming 64 are the two gate buttons and 61 are the ground loops. When I open the board the letters PED are showing on the LCD display.

My question is - if there is an issue with a particular pin on the board (61 for example) can I relocate the connections in 61 to 64 with no ill effects or will this affect the programming on the board? I assume 64 normally issues the PED command which the board is configured for opening a single gate and attaching to 61 will open both gates.


Cheers,

Rob

   
Reply
#2
(10-10-2022, 09:25 AM)RobE Wrote: Morning!

The buttons on my Rigel6 have suddenly stopped working. I've checked the connections for power (50/51) and I can see wires plugged into 60+61 and 60+64. I'm assuming 64 are the two gate buttons and 61 are the ground loops. When I open the board the letters PED are showing on the LCD display.

My question is - if there is an issue with a particular pin on the board (61 for example) can I relocate the connections in 61 to 64 with no ill effects or will this affect the programming on the board? I assume 64 normally issues the PED command which the board is configured for opening a single gate and attaching to 61 will open both gates.


Cheers,

Rob
Hi,

thanks for the message,

if you are using other pins on the board there is not an issue doing this however, the logic on the board will need to be reconfigured via the logic settings.

Many Thanks
Joe
EasyGates.co.uk - EasyGates Ltd
 
EasyGates Direct - Trade only accounts.

Smart and Secure Center - Smart Home Products
Reply
#3
Appreciate the reply, thank you.

So I could move to 61 (which defaults to StartE) and I can reprogram that. Got it. Thank you.

Also, just thinking about it. As the board constantly shows PED on LCD, could that be a short somewhere in the gate buttons that are causing the PED command to be issued and it's just shut down?
Reply
#4
(10-10-2022, 10:33 AM)RobE Wrote: Appreciate the reply, thank you.

So I could move to 61 (which defaults to StartE) and I can reprogram that. Got it. Thank you.

Also, just thinking about it. As the board constantly shows PED on LCD, could that be a short somewhere in the gate buttons that are causing the PED command to be issued and it's just shut down?

Hi Rob,

PED is pedestrian input activated. This means that whatever you have wired into the PED input is shorting to give it a constant command.

Kindest Regards,

Sam.
EasyGates.co.uk - EasyGates Ltd
 
EasyGates Direct - Trade only accounts.

Smart and Secure Center - Smart Home Products
Reply
#5
Sam - I read this and then took one of the buttons off. It dumped a load of water on the floor. Problem solved. Thank you to you both. Smile
Reply
#6
(10-10-2022, 12:59 PM)RobE Wrote: Sam - I read this and then took one of the buttons off. It dumped a load of water on the floor. Problem solved. Thank you to you both. Smile

No Problem Rob.

Sam.
EasyGates.co.uk - EasyGates Ltd
 
EasyGates Direct - Trade only accounts.

Smart and Secure Center - Smart Home Products
Reply


Possibly Related Threads…
Thread Author Replies Views Last Post
  BFT Rigel 5 - Phot message robs999 2 464 01-11-2024, 11:22 AM
Last Post: robs999
  Stressing over BFT Rigel 6 Help please Vaf888 3 709 30-10-2024, 12:54 PM
Last Post: Vaf888
  Deimos ultra bt a400 gate - not working with fobs Sootylfc 2 573 15-10-2024, 10:37 AM
Last Post: Sootylfc
  Gate radio receiver not working Zhymke 0 663 23-05-2024, 06:35 PM
Last Post: Zhymke
  BFT Rigel 5 issue Adamit 0 762 17-05-2024, 10:28 AM
Last Post: Adamit
  Just Got A Rigel 5 and need HELP!!!! rapley 2 14,431 04-05-2024, 12:47 PM
Last Post: Alee
  BFT Rigel 4 - single Gate Not Closing Tsnash 1 2,360 04-01-2024, 10:21 AM
Last Post: JoeF
  Rigel 6 conections Muttlymoo1979 0 1,994 21-07-2023, 08:52 PM
Last Post: Muttlymoo1979
  Er 10 code on RIGEL 6 control unit Eddiew 1 4,047 05-01-2023, 11:53 AM
Last Post: JoeF
  Remote only working close up Uphill 0 3,411 03-10-2021, 07:50 PM
Last Post: Uphill

Forum Jump:


Users browsing this thread: 1 Guest(s)